Ana Sayfa > Ürünler > Fabrika Otomasyonu için Sensörler > Fotoelektrik Sensörler > Ölçüm Amaçlı Işık Bariyerleri
A-GAGE MINI-ARRAY Serisi Kontrolörler—Discrete/Analog Çıkışlılar
- �r�n Spesifikasyonlar�
- �r�n Foto�raflar�
- �r�n D�k�manlar�
- �r�n Sertifikalar�
- �lgili �r�nler
�r�n Spesifikasyonlar�
Power Requirements
|
16 to 30V dc @ 1.25 A; controller alone (without emitter/receiver) requires 1 A
|
Inputs
|
Sensor input (5 connections):Emitter and receiver wire in parallel to five terminals
Trigger (Gate) input:Optically isolated, requires 10 to 30V dc (7.5 K input impedance) for gate signal |
Discrete Output
|
150 mA max. @ 30V dc
Discrete output (ALARM):One NPN (current sinking) output
OFF-state leakage current:less than 10 µA @ 30V dc
ON-state saturation voltage:less than 1V @ 10 mA; less than 1.5V @ 150 mA
|
Analog Outputs
|
MACV-1:0-10V sourcing adjustable Null and Span (20 mA current limit)
MACI-1:4-20 mA current sinking adjustable Null and Span (16 to 30V dc) |
Output Protection Circuitry
|
Protected against short circuit of outputs
|
Sensing Performance
|
Analog resolution:Span/(Number of Channels)
Analog temperature variation:0.01% of full scale/° C Analog linearity:0.1% of full scale |
Serial Data Outputs
|
RS-232, ASCII or binary data format
Baud rate:9600, 19.2K or 38.4K, 8 data bits, 1 start bit, 1 stop bit, even parity. Clear data may be suppressed; Header string may be suppressed in binary format
|
Programming
|
Use RS-232 PC-compatible computer running Window 95, 98, NT, ME, XP or 2000 operating system and Banner supplied software
|
Sensor Scan Time
|
55 microseconds per beam plus processing time. The processing time is dependent on the scan analysis and the number of active outputs. This timing assumes a straight scan, continuous and TBB mode.
Processing time:1.5 milliseconds
|
System Response Time
|
Outputs are not active for 5 seconds after system power up. Maximum response time for the sytem is two sensor scan cycles.
A scan cycle includes a sensor scan plus any serial data transmission. Serial transmission (if activated) follows every sensor scan. |
Indicators
|
Output 1 (V OUT or I OUT):
Red ON steady:indicates Output #1 is active
ALARM:
Red ON steady:indicates Output #2 is active
GATE:
Red ON steady:indicates voltage is applied to Trigger (GATE) input
ALIGN:
Green ON steady:indicates sensor is aligned (excess gain less than 1x)
DIAG1, 2, 3:used in combination to indicate system status (see data sheet)
|
Construction
|
Polycarbonate
|
Environmental Rating
|
IP20; NEMA 1
|
Operating Conditions
|
Temperature:-20° to +70° C
Relative humidity:95% (non-condensing) |