Dacel Mühendislik

Ana Sayfa > Ürünler > Fabrika Otomasyonu için Sensörler > Fotoelektrik Sensörler > Ölçüm Amaçlı Işık Bariyerleri

A-GAGE MINI-ARRAY Serisi Kontrolörler—Çift Discrete Çıkışlılar

A-GAGE MINI-ARRAY Serisi Kontrolörler—Çift Discrete Çıkışlılar

�r�n Etiketleri:   Banner

�r�n Spesifikasyonlar�

Power Requirements
16 to 30V dc @ 1.25 A; controller alone (without emitter/receiver) requires 1 A
Inputs
Sensor input (5 connections):Emitter and receiver wire in parallel to five terminals
Trigger (Gate) input:Optically isolated, requires 10 to 30V dc (7.5 K input impedance) for gate signal
Output Configuration
MAC-1:
OUTPUT 1 (OUT 1):One Reed relay contact
OUTPUT 2 (ALARM):One NPN (current sinking) output; may be configured as a second data analysis output, a system alarm output or a scan trigger output for a parallel array
MACN-1:Two NPN (current sinking) outputs; may be configured as a second data analysis output, a system alarm output or a scan trigger output for a parallel array
MACP-1:Two PNP (current sourcing) outputs; may be configured as a second data analysis output, a system alarm output or a scan trigger output for a parallel array
Output Rating
MAC-1:
Reed relay:125V ac/dc max., 10 VA max. resistive load (non-inductive)
NPN output:150 mA max. @ 30V dc max.
OFF-state leakage current:less than 10 µA @ 30V dc
ON-state saturation voltage:less than 1V @ 10 mA; less than 1.5V @ 150 mA
MACN-1 and MACP-1:150 mA max. @ 30V dc max.
OFF-state leakage current:less than 10 µA @ 30V dc
ON-state saturation voltage:less than 1V @ 10 mA; less than 1.5V @ 150 mA
Output Protection Circuitry
Protected against short circuit of outputs
Serial Data Outputs
RS-232, ASCII or binary data format
Baud rate:9600, 19.2K or 38.4K, 8 data bits, 1 start bit, 1 stop bit, even parity. Clear data may be suppressed; Header string may be suppressed in binary format
MAC-1:up to 15 controllers may be given unique address for RS-485 party line
Programming
Use RS-232 PC-compatible computer running Window 95, 98, NT, ME, XP or 2000 operating system and Banner supplied software
Sensor Scan Time
55 microseconds per beam plus processing time. The processing time is dependent on the scan analysis and the number of active outputs. This timing assumes a straight scan, continuous and TBB mode.
Processing time:1 millisecond
System Response Time
Outputs are not active for 5 seconds after system power up. Maximum response time for the sytem is two sensor scan cycles.



A scan cycle includes a sensor scan plus any serial data transmission. Serial transmission (if activated) follows every sensor scan.
Indicators
OUTPUT 1 (OUT 1):
Red ON steady:indicates Output #1 is active
ALARM:
Red ON steady:indicates Output #2 is active
GATE:
Red ON steady:indicates voltage is applied to Trigger (GATE) input
ALIGN:
Green ON steady:indicates sensor is aligned (excess gain less than 1x)
DIAG1, 2, 3:used in combination to indicate system status (see data sheet)
Construction
Polycarbonate
Environmental Rating
IP20; NEMA 1
Operating Conditions
Temperature:-20° to +70° C
Relative humidity:95% (non-condensing)

�r�n Foto�raflar�
�r�n D�k�manlar�

�r�ne ait d�k�man bulunamam��t�r.

�r�n Sertifikalar�

�r�ne ait sertifika bulunamam��t�r.

Ürünler